EN
CNEN

Power Generation Inverter

Power Generation Inverter

The distributed power generation system is composed of a hydrogen fuel cell stack engine, a power grid-connected inverter, and a power monitoring system. Hydrogen fuel cell engines consume hydrogen to produce electrical energy. The grid-connected ...

product details

      System description

The distributed power generation system is composed of a hydrogen fuel cell stack engine, a power grid-connected inverter, and a power monitoring system.

Hydrogen fuel cell engines consume hydrogen to produce electric alenergy. The grid-connected inverter includes DCF and DC/AC. DCF realizes thes table control of the current of the stack and boosts it. DC/AC completes the inverter grid-connecting function and completes the grid-connecting on the 380V distribution network side.

      Description of grid-connected inverter

This grid-connected inverter has two main parts DCF and DC/AC. The input part of the grid-connected inverter is a fuel cell stack, and the currentof the stack is controlled by DCF; the DCF output is directly connected to the high-voltage DC bus, the inverter completes the inversion, and the 380V AC is connected to the grid through the isolation transformer.

The DCF and DC/AC of the grid-connected inverter have CAN/485 communication and are equipped with a touch screen. With active and reactive control functions.

The grid-connected inverter is also equipped with input and out put EMI filters to make it work without electromagnetic pollution.

Due to the use of silicon carbide devices, the conversion efficiency is high compared to similar products.

The grid-connected inverter is anintegrated design of DCF and inverter, no need to configure a cooling pump, and it is easy to use.

The main specifications are asfollows:

Technical parameter

AC output

The output voltage

Three-phase 360V-400V

Output line connection

L1,L2,L3,PE

Output frequency

50/60Hz±10%

effectiveness

 94.5%

DC input

(Each line)

Maximum voltage Umax

800V

Maximum current Imax

400A

Maximum power Pmax

125KW

Voltage adjustment

(Each line)

Input voltage range

50-800VDC

Accuracy

0.1%Umax

Current adjustment

(Each line)

Input current range

0-400ADC

Accuracy

0.1%Imax

Power adjustment

Output power range

0-250KW

Accuracy

0.5%Pmax

Overload capacity

Voltage, current, power

110%Umax110%Imax110%Pmax

Responding speed

10%~90%h

500us

0%~10%or90%~100%

2ms

Insulation withstand voltage

DC input to housing

±3000V DC

AC input to DC input

±3000V DC

Environmental conditions

Operating temperature

0-50°C

Storage temperature

20-70°C

environment humidity

2090%R.HWithout condensation

Noise

1 meter away from the device and 1.6 meters above the ground

65dBA

Display and control panel

CV,CC,CP operating mode, active and reactive power can be adjusted, can be remotely controlled by panel control or CAN communication

Control interface

CAN485Plug and play slot

Protection function

over temperature, over voltage, over current, over power, short circuit, island and other protections

Protection class

IP21

Dimensions (width x height x depth mm)

1202 * 1903* 899

Wightkg

1700



About Foripower
Corporate Introduction
Milestones
Foripower News
PowerProducts
Fuel Cell DC/DC Converter
Vehicle-mounted DC/DC Converter
Compressor Motor Controller
Power Control Unit
Testing&Manufacture
DC Source
DC Electronic Load
Power Generation Inverter
R&D
R&D Center
Work Shop
Contact Us
Contact Us
Map
  1. +86 137 2868 6158 (dugy@foripower.com)
  2. +86 189 2602 6142
  3. Scan
    Focus on us