Product introduction |
|||||||
The FRDCS series isolated DC load with high control precision, fast response, perfect protection function and two-way operation. |
|||||||
Technical advantages |
|||||||
Bi-directional flow of DC load, which adapts to energy feedback and dynamic response of test system; |
|||||||
Can operate with 1.1 times overload for long time; |
|||||||
Wide DC voltage range; |
|||||||
Built-in power frequency isolation transformer; |
|||||||
High control precision, fast response and perfect protection function; |
|||||||
The man-machine interface adopts LCD touch screen design, which is convenient and quick to operate; |
|||||||
Max 8 units in parallel and max output current reaches 6400A. |
|||||||
Applications |
|||||||
Test and aging of Fuel cell and DC/DC converter; |
|||||||
Test and aging of power supply products; |
|||||||
Charge and discharge test of various power batteries; |
|||||||
Test and aging of E&E equipments. |
|||||||
Product parameters |
|||||||
Model |
FRDCS-50KT |
FRDCS-120KT |
FRDCS-250KT |
FRDCL-100KT |
FRDCL-150KT |
FRDCL-250KT |
|
Rating |
voltage |
60~500V |
200~850V |
480~850V |
20V~800V |
20V~800V |
50V~800V |
current |
500A |
600A |
520A |
800A |
800A |
800A |
|
power |
50kW |
120kW |
250kW |
100kW |
150kW |
250kW |
|
Response time |
< 10 ms |
||||||
Operating mode |
Constant voltage, constant current, constant resistance, and constant power |
||||||
Overload operation |
110% for long time running |
||||||
Number of units in parallel |
Max 8 units in parallel and max output current reaches 4000A |
Max 8 units in parallel and max output current reaches 6400A |
|||||
Accuracy of setting |
voltage |
≤0.1%FS+5dgt |
≤0.1%FS+5dgt |
||||
current |
≤0.5%FS |
≤0.1%FS |
|||||
AC input |
voltage |
380Vac±10%, three-phase three-wire |
|||||
frequency |
50Hz±5% |
||||||
max current |
80A |
190A |
397A |
160A |
238A |
397A |
|
Distortion rate of total input current |
|
<3%@rated power |
|||||
Power factor |
|
>0.99 |
|||||
DC component |
|
<5%@rated power |
|||||
General parameters |
dimension |
1000x1800x850 |
1200x1800x850 |
||||
weight |
1300kg |
1300kg |
1400kg |
1500kg |
1700kg |
2000kg |
|
isolation method |
built-in isolation transformer |
||||||
protection level |
IP21 |
IP21 |
|||||
operating temperature |
-30~55℃ |
||||||
highest altitude |
6000m(no derating below 3000m) |
||||||
communication method |
CAN/RS485 |
||||||
display |
Color touch screen |
||||||
cooling method |
AF(Temperature controlled forced air cooling) |
||||||
noise |
<75dB@1m |
<65dB@1m |
|||||
relative humidity |
0~95%,no condensation |
||||||
Protective function |
over-voltage & under-voltage protection |
√ |
√ |
√ |
√ |
√ |
√ |
over-current protection |
√ |
√ |
√ |
√ |
√ |
√ |
|
over-temperature protection |
√ |
√ |
√ |
√ |
√ |
√ |