DC Electronic Load

The FRDCL series products are power frequency isolated high-power DC electronic load that operates in constant voltage, constant current, constant resistance and constant power modes. Energy can flow in bidirection. It adopts SiC module t......

product details

Product description:

The FRDCL series products are power frequency isolated high-power DC electronic load that operates in constant voltage,constant current, constant resistance and constant power modes. Energy can flow in bidirection. It adopts SiC module technology, which greatly improves the efficiency, power density, thereby reducing product volume.

Features:

It has a wide DC voltage range (20-800VDC),which can be applied in various power supply;

Adopt SiC module technology, the efficiency is as high as 95%, enable high-frequency control and fast dynamic response;

With built-in power frequency transformer,safe and reliable;

Complete protection functions to ensure the safe and stable operation of the system;

Multiple units can be operated in parallel to meet supper high power supply requirement.

Typical application:

Fuel cell DC/DC converter, fuel cell engine testing and production aging;

Charge and discharge test of various types of power batteries;

Automotive driver and motor testing and aging;

Testing and aging of power electronic equipment, etc.

System Block Diagram:


Product models and technical parameters:

Product Models

FRDCL-120KTS

FRDCL-150KTS

FRDCL-200KTS

FRDCL-250KTS

FRDCL-350KTS

DC input parameters

Voltage range

20-800VDC

30-800VDC

50-800VDC

50-800VDC

50-800VDC

Maximum current

800A

Rated power

120kW

150kW

200kW

250kW

350kW

Current accuracy

<0.1%FS+5dgt

Current response

<20ms (10%FS→90%FS)

Voltage accuracy

<0.1%FS (constant voltage mode)

Voltage response

<20ms (10%FS→90%FS) (constant voltage mode)

AC output parameters

Voltage range

380VAC±10%

Phase

Three-phase three-line 3P+PE

Frequency Range

50Hz±5%

Maximum current

175A

220A

320A

400A

560A

Power Factor

≥0.99@rated power

Current harmonics THDi

<3%@rated power

DC content

<0.5%@rated power

Isolation method

Transformer isolation

System parameters

System efficiency

95%max; 92%@rated power

Parallel operation

Support 8  machines in parallel

Communication method

CAN/RS485

Local interface

Color touch screen

Operating mode

 Constant voltage mode CV, constant current mode CC, constant resistance mode CR, constant   power mode CP

Other parameters

Dimensions

W1200 * D850 * H1900 mm

Weight

1500kg

1600kg

1800kg

1900kg

1950kg

Protection level

IP21

Operating temperature

-30-55℃

Operating altitude

4000m (derating 1% for every 100m when the altitude is above 3000m)

Cooling method

AF (intelligent temperature control air cooling)

Noise

70dB@1m rated power

Relative humidity

0-95%, no condensation

Protection parameters

    DC anti-reverse connection

 The system will not work when DC is reversely connected, and the fault information will be   uploaded.

  AC phase sequence error

The system will not work when the phase is wrong, and fault information will be uploaded.

Over and under voltage protection

 With DC over-voltage and under-voltage protection. AC over-voltage and under-voltage   protection.

Over current protection

 With power module over-current protection, AC over-current protection, and DC over-current   protection.

Over temperature protection

 With inductor over-temperature protection, power module over-temperature protection, and   environmental over-temperature protection.

Leakage protection

With Power-off protection when leakage current >30mA to ensure personal safety.

Note: All the specification may change and can be customized, please refer to Foripower for the latest information.

About Foripower
Company Introduction
Milestones
Foripower News
Fuel Cell BOP
Fuel cell DC/DC Converter(non-isolated,isolated)
Integrated PCU
Fuel cell air compressor controller
Galvanic isolated DC/DC converter
Power Supply
Electrolyzer Power Supply
DC Source
DC Electronic Load
R&D
R&D Center
Work Shop
Contact Us
Contact Us
Map
  1. +86 137 2868 6158 (dugy@foripower.com)
  2. +86 189 2602 6142
  3. Scan
    Focus on us