Integrated System is a power frequency isolated energy-feeding power electronic equipment that operates in constant voltage, constant current, constant resistance and constant power modes. It can complete the activation ...

product details

Product Description:

FRDCL series fuel cell activationequipmentis a power frequency isolated energy-feeding power electronicequipment thatoperates in constant voltage, constant current, constantresistance andconstant power modes. It can complete the activation of thestack in accordancewith the activation production process of hydrogen fuelcells, while achievingenergy feedback to the electric network. It uses SiCmodule technology, whichgreatly improves system efficiency and power density,thereby reducing productvolume.                                                                                            

Features:

Wide DC voltage range (20~800VDC), which canmeet theapplication of mainstream hydrogen fuel cell activation;

Adopting SiC module technology, theefficiency is up to95%, high frequency control can be realized, and the dynamicresponse is fast;

Built-in power frequency transformer, safeand reliable;

Perfect protection function to ensure safeand stableoperation of the system;

Multiple units can be operated in parallel tomeet theapplication of large power supply.

Product model andtechnical parameters:

Product model

FRDCL-100KTSF

FRDCL-120KTSF

FRDCL-150KTSF

FRDCL-200KTSF

DC input parameters

Voltage range

20~800VDC

30~800VDC

50~800VDC

50~800VDC

Maximum current

800A

Rated power

100kW

120kW

150kW

200kW

Current accuracy

0.1%FS+5dgt

Current response

20ms (10%FS→90%FS)

Voltage accuracy

0.1%FSConstant voltage mode

Voltage response

20ms (10%FS→90%FS) Constant voltage mode

AC output parameters                                                                                                                                                   

voltage range

400VAC±10%

Phase

Three-phase three-wire 3P+PE

Frequency range

50Hz±5%

Maximum current

160A

175A

220A

320A

Power factor

≥0.99@ rated power

Current harmonics

3%@ rated power

DC component

0.5%@ rated power

Isolation

Power frequency transformer isolation

System parameters

System efficiency

95%max;>92%@rated power

Operation in parallel

Maximum 8

communication method

CAN /RS485

Interface

Color touch screen

Operating mode

Constant voltage mode, Constant current mode, Constant resistance mode, Constant power mode

Others

Dimension

W1202*D899*H1903 mm

Weight

1400kg

1500kg

1600kg

1800kg

Protection class

IP21

Operating temperature

-30~55

Altitude

6000mDerating above 3000m

Cooling

AFIntelligent temperature control air cooling

Noise

70dB@1m rated power

Relative humidity

0~95%no condensation

Protection functions

DC anti-reverse connection

the system does not work when the DC is reversed, and the fault information is uploaded

AC phase sequence error

the system does not work when the phase is wrong, and upload fault information

Over voltage protection

DC over and under voltage protection, AC over and under voltage protection.

Over current protection

power module over current protection, AC over current protection, DC over current protection

Over temperature protection

inductance over temperature protection, power module over temperature protection, environmental over temperature protection

Current leakage protection

Power off protection when leakage current > 30mA to ensure personal safety.

About Foripower
Company Introduction
Milestones
Foripower News
Fuel Cell BOP
Fuel cell DC/DC Converter(non-isolated,isolated)
Integrated PCU
Fuel cell air compressor controller
Galvanic isolated DC/DC converter
Power Supply
Electrolyzer Power Supply
DC Source
DC Electronic Load
R&D
R&D Center
Work Shop
Contact Us
Contact Us
Map
  1. +86 137 2868 6158 (dugy@foripower.com)
  2. +86 189 2602 6142
  3. Scan
    Focus on us